MTL SGS TEST LIST (1)
(Seating)
(Combines Adult and Children’s sizes,:Chairs,
Barstools, Ottomans,)
Quality test
standardmethod
ng DesignFeatures(标签设计
特点)
ctions指示 说明
Criteria(标准)
The actuality
must keep consistency(一致性) with the claim(要
求).
Shall be included if necessary. Shall include
assembly, mounting
(装备), use, maintenance(维护),
cleaning and safety information
as required in
the language(s) applicable to the
destination(目的
地) country(s) with no errors or
spelling mistakes.(地名写错)
Shall be easy to
follow and accurate.
t sizeweight产品尺寸 重量
Statement
Report actual. Shall comply with
any claims (-0%, +3%)
inches or greater are
used in inner packaging, the following
warning
statement must be printed on at least one side of
each bag
in English, French and Spanish:
5. Lead In Surface Coating(被复盖)
6.
Workmanship(工艺) Level
Shall not exceed 600 ppm
(0.06% by weight) total lead
?
?
?
?
?
?
?
?
?
No major
defects(缺点)。
No components(成分) missing,
malformed(畸形的) or
fractured (破裂)
No
hardware missing
Smoothly ground welds(接合),
not over-ground and free
of pits(凹陷) and
splatter(说话结巴)
No burrs(喉音)
No loose
components and unsecured fastening where
rigidity(硬度) is required
In the case of
wood (e.g. laminates(薄板) proper and
uniform(一致的) adhesion(支撑)
No scratches,
dents(凹痕), cracks(裂缝), marred(损
坏) or
discolored surface
In the case of molded
plastic, consistent and concise form
and no
defects evidencing(明显的) of overuse(过度的)
of
mold。
?
?
?
?
?
?
7.
Sharp Points and Edges
8. Cross Cut Adhesion
Finished edges and seams(衔接口)
Accurate and
consistent(调和的) painting
Components even in
color, uniform clarity
All seams and
components in even alignment(结盟)
Accurate and
consistent painting
Components even in color,
uniform clarity(清楚)
Results
4. Costco Plastic Bag Warning
If plastic bags (of any thickness) with a
perimeter(周长) of 14
Shall have no sharp edges
or sharp points on any component other
than
those required for functional use.
Plating
finish must stay affixed – using a
utility(万能)knife, cut a
grid of 16 squares.
Use 3M masking tape (#202), apply to the
grid.
Remove to see if plating finish remains
intact.(完整无缺)
9. Flammability(可燃性) of
Upholstery Must comply with California Bureau of
Home Furnishings Bulletin
Materials
10. Finger Entrapment
116117
Shall meet the requirements intended to
eliminate (消除) the
possible hazard (危险) that
may be caused by changing
clearances or
permanent(永久的) entrapment and pinching(收
宿)of
fixed openings.(<5mm or >13mm)
11. Resistance
To Hot Water
11 Effects Of Extreme Temperature
12. Resistance(抵抗力) To Corrosion
(侵蚀)
(Metal Components)
13. Effects Of Humidity(湿度)
Pour 25 mL. of boiling water and allow
cooling. Dry surface, Shall
be no graying(灰色)
or spotting(斑点)
24 Hours At -32° F And 140°F -
No failure
corrosion or visual change.
No
change after 24 hours. @ 95% RH & 100°F
Shall withstand(抵挡) 24 hours in 1% salt spray
(fog) with no
14. Stain(污点) Resistance- (Do
not Various food materials – should resist
permanent staining.( After 2
test on picnic
table hours, remove)
racks) 1. French’s
Mustard t2. Heinz Ketchup3. Ragu Spaghetti sauce
(original)
4. Folgers Instant Coffee 5.
Welch’s Grape Juice6. Kraft BBQ
Sauce
(original) Red Wine
15 Resistance to
Scratching Marring No scratching or marring of
surface (3 cycles of 6” back and forth.)
Other Surfaces
16. Caster Performance (If
Supplied)
17. Rear Stability背后的稳定性
Conduct
with and without levelers. Note if levelers
become bent
or come off. Note any damage
defects (bentbroken levelers)
Max 5 lb pull
to move under 200 lb load
Lbs. children)
weight placed on the seat (Strap). Force is
applied
in rearward direction against 1inch
obstruction. Report result
when seat is in
minimum, midpoint and maximum position
18.
Front Stability
Ottomans)
19. Tip
Resistance (Stools Only)
20. Stability (Stools
Only)
21. Base Durability(耐用力)
The chair
is obstructed(阻塞) by 1 inch bar in the front base,
force shall not be less than 40% of the total
chair weight.
Min 10 degree with 150 Lbs.
(Children 100 Lbs.) distributed load,
no tip-
over
Min 20 Lbs. pull force after 150 Lbs.
(Children 100 Lbs.) distributed
load on the
seat, no tip-over
No structural(结构的) failure
or permanent(永久的) deformation
(变形) under 400
Lbs. (225 Lbs. children) static (静力的) load
for
60 minutes. For multi seatback positions, report
result when
seat back is in minimum, midpoint,
and maximum positions for 20
minutes each.
22. Front Seating Capability
(Excludes
Barstools & Ottomans)
23. Impact(碰撞)
Durability
without cushion(垫子))
No
structural breakage, max ? inch deformation(变形)
when 225
children) test load free falls from
6 inch to the center of the seat.
For multi
seatback positions, report result when seat back
is in
minimum, midpoint, and maximum
positions. If chair has levelers,
conduct
test with levelers fully extended then rotated(旋转)
inward
(向内的) two revolutions.
(*If
applicable – perform with and Lbs. (200 Lbs.
folding chairs, 175 Lbs ottomans, 100 Lbs.
No
failure under 300 Lbs. (135 Lbs. children) loading
at edge (6 In.)
(Excludes(把 …除外)
Barstools & tipping force is measured in the 45°
to the test platform. The tipping
Min 35
Lbs. (30 Lbs. children) tipping force with a 173
Lbs. (100
24. Back Pull
Durability后拉力 耐久力
25. Arm Strength Test
(Vertical垂直的)
No failure at 100 Lbs. (60
Lbs. children) for 1 min. applied(应用) to
90°
from back at 16 inch above the seat.
No
permanent deformation at 300 Lbs. (90 Lbs.
children) for 1 min.
The vertical(吹垂直的) load
is uniformly(均一的) applied through
a 5 inch
wide board across both arms – No failure
deformation
26.Arm Strength Test
(Horizontal水平
的)
No permanent deformation
at 75 Lbs. (45 Lbs. children) for 1 min.
The
load is applied to the armrest horizontally at the
most forward
point of the armrest area.
No
failure or permanent deformation at 75 Lbs. (40
Lbs. Child
folding chairs) applied to each
leg at 1 inch from the end of the leg.
Force
is applied in four directions (Forward, rearward,
side and
side) for 1 minute.
27. Leg
Strength腿力量
36. Moisture Content (%)
(Solid Wood 8% - 12% (Do not test on MDF)
Only)湿度
37. Lightfastness (耐光性) Class 4.0
@ 20 hrs - Test up to 5 majormain components
MTL SGS TEST
LIST (2)
(CD chest)
Quality test
standardmethod
ng DesignFeatures
ctions
Criteria
The actuality must keep
consistency with the claim.
use, maintenance,
cleaning and safety information as required in
the language(s) applicable to the destination
country(s) with no
errors or spelling
mistakes. Shall be easy to follow and accurate.
t sizeweight
Statement
Report actual.
Shall comply with any claims (-0%, +3%)
greater are used in inner packaging, the
following warning
statement must be printed on
at least one side of each bag in
English,
French and Spanish:
5. Lead In Surface Coating
6. Workmanship Level
Shall not exceed(超越)
600 ppm (0.06% by weight) total lead
?
?
?
?
?
?
?
No major
defects
No components missing, malformed(难看的)
or fractured
(破裂)
No hardware missing
Smoothly ground welds(接合), not over-ground and
free
of pits and splatter
No burrs
No
loose components and unsecured fastening where
rigidity (硬度)is required
In the case of
wood (e.g. laminates薄片) proper and
Results
Shall be included
if necessary. Shall include assembly, mounting,
4. Costco Plastic Bag Warning If plastic bags
(of any thickness) with a perimeter of 14 inches
or
uniform adhesion
?
?
?
?
?
7. Sharp Points and Edges
8. Cross Cut Adhesion(粘着力)
No
scratches, dents, cracks, marred or discolored
surface
In the case of molded plastic,
consistent and concise form
and no defects
evidencing迹象 of overuse of mold.
Finished
edges and seams
Accurate and consistent
painting
Components even in color, uniform
clarity
Shall have no sharp edges or sharp
points on any component other
than those
required for functional use.
Plating (电镀)
finish must stay affixed(粘贴) – using a utility
knife, cut a grid(格子) of 16 squares. Use 3M
masking tape
(#202), apply to the grid.
Remove to see if plating finish remains
intact.(完整无缺的)
9. Glass Top Thickness (Raw
Edge If less than 7.6 mm, tempered glass required.
If 7.6 mm or greater,
(mm)
(mm)
Test
Filled and Unfilled.)
11 Effects Of Extreme
Temperature
Components)
13. Effects Of
Humidity
picnic table racks)
tempered
glass not required.
tempered glass not
required
and configuration, without tip over.
24 Hours At -32° F And 140°F - No failure
visual change.
No change after 24 hours. @
95% RH & 100°F
hours, remove)
1. French’s
Mustard t2. Heinz Ketchup3. Ragu Spaghetti sauce
(original) “
5. Folgers Instant Coffee
5. Welch’s Grape Juice6. Kraft BBQ
Sauce
(original) Red Wine
15 Resistance to
Scratching Marring No scratching or marring of
surface (3 cycles of 6” back and forth.)
Other Surfaces
16. Handle Strength
17.
Drop Test
Or Greater Than 20 Inches Width)
Conduct with and without levelers. Note if
levelers become bent
or come off. Note any
damage defects (bentbroken levelers)
Shall
withstand 1.5 x claimed load or 50 lbs for 1 hour
10. Glass top Thickness
(Encased) If less than 4.6 mm, tempered glass
required. If 4.6 mm or greater,
11. Stability
– Static (If Applicable – Shall withstand an 8°
angle of incline, in the least stable positioning
12. Resistance To Corrosion (Metal Shall
withstand 24 hours in 1% salt spray (fog) with no
corrosion or
14. Stain Resistance- (Do not
test on Various food materials – should resist
permanent staining.( After 2
Raise the end of
the long axis of the storage unit to the specified
shall be no damage as a result of the test.
Drop Height 10 inches (Unit Weight 10-49 Lbs)
6 Inches (Unit
Weight 50-99 Lbs
4 Inches (Unit Weight 100-200 Lbs)
2 Inches (Unit Weight >200 Lbs):
(For Units 30
Inches Height Or Over, height and release the end.
Repeat test for the other end. There
18. Drop
Test (For Units Under 30 No breakage or
separation after 3 drops from 12 inches on vinyl
tile
Inches Height And Less Than 20 over
concrete.
Inches Width Or With Total Weight
CDAudio tapeor Video tape Holder –
Under 10
Lbs)
Only)
No failure or
deformation after 1 drop on end from 10 inches
19. Moisture Content (%)(Solid Wood 8% - 12%
(Do not test on MDF)
20. Cycle
Test Test for Moving 100 times cycles use of
moving components – no failure and all
Components
21. Finger Entrapment
components must have and maintain a smooth
uniform movement
throughout each cycle
Shall meet the requirements intended to
eliminate the possible
hazard that may be
caused by changing clearances or permanent
entrapment and pinching of fixed
openings.(<5mm or >13mm)
22. Resistance To Hot
Water Pour 25 ml of boiling water and allow
cooling. Dry surface, Shall be
no graying or
spotting
23. Cap Removal Strength on end of
Shall not separate minimum holding force @ 5.0
lbs.
tubes (or cap covers on screw ends)
24. Caster Performance (If Supplied)
25.
CasterRoller Durability
Max 20 lbs. pull to
move under 200 lbs. load.
Shall result in no
adverse effects on rolling after use tests.
Rolling 100 meters on smooth concrete floor
under uniformly
distributed load:
200 lbs
for Serving CartRack 500 lbs for larger
CabinetsShelves
26 Drawer Loading Capacity
Magazine, Shoe, Coat or Wine Racks)
Max. 14 in. deformation @ 10 lbs distributed
load drawer
greater than ? inch.
< 8 In.
Depth (3 Lbs. X ShelfTop Width) 8 - 16 In. Depth
(5 Lbs. X
ShelfTop Width)
>16 In. Depth (7
Lbs. X ShelfTop Width)
Or 1.5 x Claimed
Capacity
28. Concentrated Load No structural
failure or more than ? inches deformation when
load
(For Floor Standing Units Up To 38 is
applied to a 12 inches diameter disk located such
that the center
Inches Height, Except
Magazine, of the disk is 6 inches from the edge of
the top surface
Shoe, Coat or Wine Racks)
29. Stability
(For Units Over 42 inches
Height)
30. Stability
Inches Height)
31. Racking Test
32. Leg Strength
(SideFront)
Top Surface Area > 4 sq ft –
300 lbs< 4 sq ft – 200 lbs
No tip-over should
occur under the following conditions
No tip
over should occur under the following conditions
1 inches from the edge of 12 inches disk
>
4 sq ft – 100 lbs<4 sq ft - 90 lbs
No
structural damage or deformation when the unit is
raised 45
degrees from the floor
75 lbs
(40 lbs if Unit is less than 30 inches height)
applied vertically
to the leg at 1inch from
the end of the leg. Force is applied in 4
directions (Forwardrearward, side to side).
No failurepermanent
deformation
33. Impact
Durability
enance Loading
No structural
breakage when 200 lbs test load falls 6 inches to
the
center of the top.
Test For units
over 30 Inch height, apply a 50 lb downward force
for 1
minute to any portion of the unit
within 30 inches of the floor that is
likely
to support part or all of a child’s weight. There
shall be no
tip-over of the unit
35.
Drawer Operability Max 10 lbs pull force with
distributed drawer load (30 lbscubic ft –
10
lbs minimum)
(Tip-Over Resistance)
Horizontal force of 40 lbs or an angle >
10 deg before tipping occur
27. Distributed Load Test(Except There shall
be no structural failure or permanent deformation
(For Floor Standing Units Up to 42 Must not
have any one leg lift off the floor when test load
is applied
36. Extendible
ShelvesSupports
Max 10 lbs pull force
with distributed load (per table 1a, see last
page of protocol)
37. Lightfastness
(Indoor Use –For Class 4.0 @ 20 hrs - Test up to 5
majormain components
Hard Materials Only)
MTL SGS TEST LIST (3)
(Home Entertainment Center TV Stand (UL 1678
4
th
Ed.)
Quality test
standardmethod
Criteria
ng
DesignFeatures
The actuality must keep
consistency with the claim.
ctions
Results
Shall be included if
necessary. Shall include assembly,
mounting,
use, maintenance, cleaning and safety information
as required in the language(s) applicable to
the destination
country(s) with no errors or
spelling mistakes. Shall be easy
to follow and
accurate.
Report actual. Shall comply with any
claims (-0%, +3%)
3.
product sizeweight
4. Costco Plastic Bag Warning
If plastic
bags (of any thickness) with a perimeter of 14
inches or greater
are used in inner
packaging, the following warning statement must be
Statement
printed on at least one side
of each bag in English, French and Spanish:
5. Lead In Surface Coating
6.
Workmanship Level
Shall not exceed 600 ppm
(0.06% by weight) total lead
?
?
?
?
No major defects
No components
missing, malformed or fractured
No hardware
missing
Smoothly ground welds, not over-ground
and free of
pits and splatter
?
No burrs
? No loose components and unsecured
fastening where
rigidity is required
? In
the case of wood (e.g. laminates) proper and
uniform adhesion
? No scratches, dents,
cracks, marred or discolored
surface
? In
the case of molded plastic, consistent and concise
form and no defects evidencing of overuse of
mold.
? Finished edges and seams
?
Accurate and consistent painting
? Components
even in color, uniform clarity
Shall have no
sharp edges or sharp points on any component
other than those required for functional use.
Plating finish must stay affixed – using a
utility knife, cut a
grid of 16 squares. Use
3M masking tape (#202), apply to
the grid.
Remove to see if plating finish remains intact.
7. Sharp Points and Edges
8. Cross
Cut Adhesion
9. Glass Top
Thickness (Raw Edge If less than 7.6 mm, tempered
glass required. If 7.6 mm or
(mm) greater,
tempered glass not required.
10. Glass top
Thickness (Encased) If less than 4.6 mm, tempered
glass required. If 4.6 mm or
(mm) greater,
tempered glass not required
11. Stability –
Static (If Applicable – Shall withstand an 8°
angle of incline, in the least stable
Test
Filled and Unfilled.) positioning and
configuration, without tip over.
11 Effects Of
Extreme Temperature 24 Hours At -32° F And 140°F -
No failure
12. Resistance To Corrosion (Metal
Shall withstand 24 hours in 1% salt spray (fog)
with no
Components) corrosion or visual
change.
13. Effects Of Humidity No change
after 24 hours. @ 95% RH & 100°F
14. Stain
Resistance- (Do not test on Various food materials
– should resist permanent
picnic table
racks) staining.( After 2 hours, remove)
1.
French’s Mustard t2. Heinz Ketchup3. Ragu
Spaghetti sauce
(original) “
6. Folgers
Instant Coffee 5. Welch’s Grape Juice6. Kraft
BBQ Sauce (original) Red Wine
15
Resistance to Scratching Marring
No
scratching or marring of surface (3 cycles of 6”
back and
Other Surfaces forth.)Conduct
with and without levelers .Note if levelers
become bent or come off. Note any damage
defects
(bentbroken levelers)
16. Caster
Performance (If Supplied)
17. Temperature
Stability Test
Max 5 Lbs. pull to move under
200 Lbs. load
A cart or stand employing
polymeric materials in its
construction shall
withstand 7 hours of exposure in a
full-draft
circulating air oven maintained at 70 ?C without
any
shrinkage, warpage or other distortion.
18. Tip Stability Test –Conventional A cart or
stand not intended for use with a television,
shall not
Television tip over when placed at
the center of a plane inclined to make
an
angle of 10 degrees with the horizontal and loaded
as
specified in table 13.1 of this standard. A
cart or stand
intended for use with a
television shall not tip over when
placed at
the center of a plane to 10 degrees with the
horizontal with the surface intended to
support a television
loaded with the simulated
television load described in section
13.4. If
the manufacturer specifies a television range,
then the
test is to be conducted with the
simulated loads within the
range specified.
The test is to be conducted according to all of
the stipulations of this section of the
standard.
19. Moisture Content (%)(Solid 8% -
12% (Do not test on MDF)
Wood Only)
20. Tip Stability Test – Flat Panel TV As
described in section, shall not tip over when
placed at the
Rack center of a plane to 10°
with the horizontal with a simulated
load per
table 13.2 attached to the flat panel TV rack.
21. Loading Test – Individual A cart or stand
shall be constructed so that there is no collapse
Loading (Conventional TV Stand ) or permanent
damage that results in risk of injury to persons
when each supporting surface it individually
loaded with:
a) Two times the load specified
in table 13.1 plus 100
pounds for the surface intended to support a
television;
b) Four times the load
specified in table 13.1, not to
exceed 100
pounds for all other supporting surfaces;
or
c) The maximum intended load for a dedicated
storage
area intended to accommodate a
specific accessory.
Each supporting surface
shall be tested for one minute with
the other
supporting surfaces unloaded.
22. Finger
Entrapment Shall meet the requirements intended to
eliminate the possible
hazard that may be
caused by changing clearances or
permanent
entrapment and pinching of fixed openings.(<5mm
or >13mm)
23. Loading Test - Individual A
cart or stand shall be constructed so that there
is no collapse
Loading or permanent damage
that results in risk of injury to persons
(Flat Panel TV Stand ) when each supporting
surface it individually loaded with:
a) 200
pounds for flat panel TV rack;
b) Four times
the load specified in Table 13.1, not to exceed
100 pounds for all other supporting surfaces;
or
c) The maximum intended load for a
dedicated storage area
intended to accommodate
a specific accessory.
Each supporting surface
shall be tested for one minute with
the other
supporting surfaces unloaded.
24. Loading Test
– Simultaneous The cart or stand shall be
constructed so that there is no
Loading
collapse or permanent damage that results in a
risk of injury
(Conventional TV Stand ) to
persons when each supporting surface is
simultaneously
loaded with the load specified
in table 13.1 for a period of one
minute.
Modification = test to 300 pounds.
25. Loading
Test - Simultaneous The cart or stand shall be
constructed so that there is no
Loading
collapse or permanent damage that results in a
risk of injury
(Flat Panel TV Stand ) to
persons when each supporting surface is
simultaneously
loaded with the load specified
in Table 13.1 for a period of
one minute.
Modification = Test flat panel TV rack to 200 Lbs
or manufacturer’s specified load, whichever is
greater.
26 Wall or Ceiling Mounting A shelf
or similar product intended for direct wall
mounting
Security Test shall be so
constructed so that there is no cracking or
breaking
or damage to the mounting bracket,
its securing means and
the portion of the
shelf attached to it when each supporting
surface is both individually and
simultaneously loaded with
four times the load
specified in table 13.1 for one minute
27.
Appurtenance Loading Test
(Tip-Over
Resistance)
For units over 30 Inch height,
apply a 50 Lb downward force
for 1 minute to
any portion of the unit within 30 inches of the
floor that is likely to support part or all of
a child’s weight.
There shall be no tip-over
of the unit
Structural glass parts shall
comply with the requirements in
the impact
test, section 19. A decorative glass part having
an
28. Impact Test – Glass Parts
area greater than 1 Ft
2
or having a minor dimension greater
than 18
inches, shall not be broken, shattered (totally or
in
part), or displaced when tested as
described in 20.3 of this
section.
29.Impact Durability (B) - for units
No
structural breakage when 200 Lbs. test load falls
free from
under 30 inches high 6 In. to the
center of the top with no static load in the other
half of the top
30. Front Seating
Capability (For No failure under 300 Lbs loading
at 6 inches at edge (6
Floor Standing Units
Under 30 Inch inches)
Height And Flat
Horizontal Top
Surface Which May Be Sat On)
31. Drawer Operability
32. Racking Test
33. Leg Strength
After distributed loading
of 10 Lbs. drawer, max. 10 Lbs.
pull force
No structural damage or deformation when the
unit is raised
45° from the floor
No
structural failure at 75 Lbs. (40 Lbs. if folding
legs or if
children’s furniture) applied
vertically to each leg type at 1
inch from the
end of the leg. Force is applied in four
directions (forward rearward, side to side)
Each enclosed area of a cart or stand intended
to
accommodate electrical equipment shall be
provided with a
means for ventilation when the
equipment is installed.
Max 10 lbs pull force
with distributed drawer load (30
lbscubic ft
– 10 lbs minimum)
Max 10 lbs pull force with
distributed load (per table 1a, see
last page
of protocol)
34. Ventilation
35.
Drawer Operability
36. Extendible
ShelvesSupports
37. Lightfastness (Indoor Use
–For Class 4.0 @ 20 hrs - Test up to 5 majormain
components
Hard Materials Only)
Table 13.1
Supporting surface loading parameters
Surface Type
TV shelf
Other
supporting surface
Dedicated storage area
Load
Weight specified in Table 13.2 or
manufacturer’s specified load, whichever
is greater.
Manufacturer specified
load or 25 lbs.,
whichever is greater
Fully loaded with intended load
able 13.2 Simulated Television Load
ParametersT
Maximum screen diagonal measurement
ecommended for use with surface, inches
(cm)
CRT TELEVISIONS
Up to 13 (33.02)
14 – 16 (35.56 – 40.64)
17 – 20 (43.18 –
50.80)
21 – 24 (53.34 – 60.96)
25 – 27
(63.50 – 68.58)
28 – 32 (71.12 – 81.28)
33
– 35 (83.82 – 88.90)
36 – 40 (91.44 – 101.60)
Total weight
b
, lbs (kg)
25 (11.34)
35 (15.88)
50 (22.68)
70 (31.75)
95 (43.09)
135 (61.23)
175 (79.38)
240 (108.86)
Total weight
b
, lbs (kg)
80 (36.3)
100 (45.4)
135 (61.4)
135 (61.4)
135 (61.4)
Height above supporting
surface to center of support
rod, inches
(cm)
6-34 (17.15)
7-12 (19.05)
9
(22.86)
10 (25.40)
11 (27.94)
13
(33.02)
15 (38.10)
17 (43.18)
Height
above supporting
surface to center of support
rod, inches (cm)
16 (40.6)
18 (45.7)
20 (50.8)
21(53.3)
22 (55.8)
Angle of unstable equilibrium
25°
25°
22°
21°
20°
(12 °)
(12 °)
(12 °)
Maximum screen diagonal measurement
ecommended for use with surface, inches
(cm)
PLASMA LCD TELEVISIONS
30 – 40
(76.2 – 101.6)
41 – 45 (104.1 – 114.3)
46
- 50 (116.8 – 127.0)
51 – 55 (129.4 – 139.7)
56 – 60 (142.2 – 152.4)
Angle of
unstable equilibrium
12 °
12 °
12 °
12 °
12 °
The fixture shall be stable
in the forward direction at the angle specified
and become unstable (tip over) when the angle is
increased b
degree.
Includes weight of text
fixture.
MTL SGS TEST LIST (4)
Bed (For
Trundle and Regular Beds, Adult use)
Quality
test standardmethod
ng DesignFeatures
ctions
Criteria
The actuality must
keep consistency with the claim.
Results
Shall be included if necessary. Shall
include assembly,
mounting, use, maintenance,
cleaning and safety information
as required in
the language(s) applicable to the destination
country(s) with no errors or spelling
mistakes. Shall be easy
to follow and
accurate.
Report actual. Shall
comply with any claims (-0%, +3%)
3.
product sizeweight
4. Costco Plastic
Bag Warning
If plastic bags (of any thickness)
with a perimeter of 14 inches or
greater are
used in inner packaging, the following warning
statement
Statement
must be printed on
at least one side of each bag in English, French
and
Spanish:
5. Lead In Surface
Coating
6. Workmanship Level
Shall not
exceed 600 ppm (0.06% by weight) total lead
?
No major defects
? No components missing,
malformed or fractured
? No hardware missing
? Smoothly
ground welds, not over-ground and free of
pits
and splatter
? No burrs
? No loose
components and unsecured fastening where
rigidity is required
? In the case of wood
(e.g. laminates) proper and
uniform adhesion
? No scratches, dents, cracks, marred or
discolored
surface
? In the case of molded
plastic, consistent and concise
form and no
defects evidencing of overuse of mold.
?
Finished edges and seams
? Accurate and
consistent painting
? Components even in
color, uniform clarity
? All seams and
components in even alignment
Shall have no
sharp edges or sharp points on any component
other than those required for functional use.
Plating finish must stay affixed – using a
utility knife, cut a
grid of 16 squares. Use
3M masking tape (#202), apply to
the grid.
Remove to see if plating finish remains intact.
Applicable by design – must sit level with no
wobbling on a
flat level surface. The top
must also be levelparallel
compared to the
bottom.
7. Sharp Points and Edges
8. Cross
Cut Adhesion
9. Level
10. Cycle Test Test
For Moving 100 times cycles use of moving
components – no failure and
Components all
components must have and maintain a smooth uniform
movement throughout each cycle. (All
functional parts must
be evenly aligned at the
start of the test and remain evenly
aligned.)
11. Folding Mechanisms and Hinges Shall meet
the requirements to eliminate the possible
crushing, laceration or pinching hazards that
might occur in
folding mechanisms and hinges.
24 Hours At -32° F And 140°F - No failure 11
Effects Of Extreme Temperature
12. Resistance
To Corrosion (Metal Shall withstand 24 hours in 1%
salt spray (fog) with no
Components)
corrosion or visual change.
13. Effects Of
Humidity No change after 24 hours. @ 95% RH &
100°F
14. Stain Resistance- (Do not test on
Various food materials – should resist permanent
picnic table racks) staining.( After 2 hours,
remove)
1. French’s Mustard t2. Heinz
Ketchup3. Ragu Spaghetti sauce
(original) “
7. Folgers Instant Coffee 5. Welch’s Grape
Juice6. Kraft
BBQ Sauce (original) Red Wine
15 Resistance to Scratching Marring
No
scratching or marring of surface (3 cycles of 6”
back and
Other Surfaces forth.)Conduct
with and without levelers .Note if levelers
become bent or come off. Note any damage
defects
(bentbroken levelers)
16. Caster
Performance (If Supplied)
Shall not
separate minimum holding force @ 5.0 lbs
17. Cap Removal Strength
(on end of Shall not separate minimum holding
force @ 5.0 lbs
tubes) (or Cap Covers on
screw
ends)
18. Drop Impact Test
One end of the bed is dropped from a height of
10 inches.
No failurepermanent deformation
19. Moisture Content (%)(Solid 8% - 12% (Do
not test on MDF)
Wood Only)
20.
Distributed Static Load No structural failure or
greater than 14 inch permanent
deformation
after loading for 60 minutes
Single - 500 lbs
FullQueenKing – 800 lbs
21. Lightfastness
(Indoor Use –For Class 4.0 @ 20 hrs - Test up to 5
majormain components
Hard Materials Only)
MTL
SGS TEST LIST (5)
(Bunk Bed)
Quality test
standardmethod
ng DesignFeatures
ctions
Criteria
The actuality must
keep consistency with the claim.
Results
Shall be included if necessary. Shall
include assembly,
mounting, use, maintenance,
cleaning and safety information
as required in
the language(s) applicable to the destination
country(s) with no errors or spelling
mistakes. Shall be easy
to follow and
accurate.
Report actual. Shall
comply with any claims (-0%, +3%)
3.
product sizeweight
4. Costco Plastic
Bag Warning
If plastic bags (of any thickness)
with a perimeter of 14 inches or
greater are
used in inner packaging, the following warning
statement
Statement
must be printed on
at least one side of each bag in English, French
and
Spanish:
5. Lead In Surface
Coating
6. Workmanship Level
Shall not
exceed 600 ppm (0.06% by weight) total lead
?
?
?
?
No major defects
No
components missing, malformed or fractured
No
hardware missing
Smoothly ground welds, not
over-ground and free of
pits and splatter
? No burrs
? No loose components and
unsecured fastening where
rigidity is required
? In the case of wood
(e.g. laminates) proper and
uniform adhesion
? No scratches, dents, cracks, marred or
discolored
surface
? In the case of molded
plastic, consistent and concise
form and no
defects evidencing of overuse of mold.
?
Finished edges and seams
? Accurate and
consistent painting
? Components even in
color, uniform clarity
Shall have no sharp
edges or sharp points on any component
other
than those required for functional use.
Plating finish must stay affixed – using a
utility knife, cut a
grid of 16 squares. Use
3M masking tape (#202), apply to
the grid.
Remove to see if plating finish remains intact.
Products intended for children under 36 months
(3 years) of
age shall not include removable,
liberated components, or
fragments of products
after use and abuse that are small
enough
(without being compressed) to fit entirely within
the
small parts cylinder
7. Sharp Points
and Edges
8. Cross Cut Adhesion
9. Small
Objects
10. Accessible Edges Accessible
Products intended for children under 8 years of
age shall not
Points have accessible,
potentially hazardous sharp edges before or
after use and abuse testing
11. Level
Applicable by design – must sit level with no
wobbling on a
flat level surface. The top
must also be levelparallel
compared to the
bottom.
24 Hours At -32° F And 140°F - No
failure 11 Effects Of Extreme Temperature
12.
Resistance To Corrosion (Metal Shall withstand 24
hours in 1% salt spray (fog) with no
Components) corrosion or visual change.
13. Effects Of Humidity No change after 24
hours. @ 95% RH & 100°F
14. Stain Resistance-
(Do not test on Various food materials – should
resist permanent
picnic table racks)
staining.( After 2 hours, remove)
1. French’s
Mustard t2. Heinz Ketchup3. Ragu Spaghetti sauce
(original) “
8. Folgers Instant Coffee
5. Welch’s Grape Juice6. Kraft
BBQ Sauce
(original) Red Wine
15 Resistance to
Scratching Marring
No scratching or marring
of surface (3 cycles of 6” back and
Other
Surfaces forth.)Conduct with and without levelers
.Note if levelers
become bent or come off.
Note any damage defects
(bentbroken levelers)
16. Cycle Test Test for Moving 100 times
cycles use of moving components – no failure and
Components all components must have and
maintain a smooth uniform
movement throughout
each cycle. (All functional parts must
be
evenly aligned at the start of the test and remain
evenly
aligned.)
17. Folding Mechanisms
and Hinges
Shall meet the requirements to
eliminate the possible
crushing, laceration or pinching hazards that
might occur in
folding mechanisms and hinges.
18. Resistance To Hot Water Pour 25ml of
boiling water and allow cooling. Dry surface,
Shall be no graying or spotting
19. Moisture Content (%)(Solid 8% - 12% (Do
not test on MDF)
Wood Only)
20. Cap
Removal Strength (On end of Shall not separate
minimum holding force @ 5.0 lbs.
tubes) OR
(Cap Covers on Screw
Ends)
21. Mechanical
Hazards
A furniture article intended for use
by a child shall not present a
mechanical
hazard in normal use or when subjected to
reasonable
foreseeable abuse:
? From
fracture, fragmentation, or disassembly of the
article
? From propulsion of the article
or any part or accessory
thereof
? From
points or other protrusions, surfaces, edges,
openings or closures
? From moving parts
? From lack or insufficiency of controls to
reduce or stop
motion
? As a result of
self-adhering characteristics of the article
?
Because the article or any part or accessory
thereof may
be aspirated or ingested
?
Because of instability
Because of any other
aspect of the articles’ design or
manufacture.
22. Fit of Top Bed to Bottom Bed The bed post
shall be designed so that the minimum height of
lift to allow horizontal disengagement of the
top bed from the
bottom bed shall be 1
?
may be used to prevent disengagement of the
top bed from
the bottom bed.
23. Mattress
and Foundation Size and Shall be no gaps between
interior bed structure and the edges
Fit of
the mattress and foundation that will permit
complete
passage of wedge block when tested in
accordance with 5.2.
24. Foundation Support
System Shall confine the horizontal position of
the mattress and the
foundation and shall
prohibit the mattress and foundation
from
falling into the clearance over the lower bunk or
to the
floor when it is manipulated.
A
minimum of two per bed are required if cross-
members
are utilized.
They shall be spaced
if more than two are utilized so that the
distance between adjacent cross-members or
between the
cross-members and the bed end
structures will not permit
complete passage of
the wedge block or will allow complete
passage
of both the wedge block and the 9 in.(230 mm)
diameter rigid sphere when
tested in accordance with 5.8.
25. Bolt-On
Side Rails
? Shall be secured at each end by
two bolts with a
(Attach at their ends or on
their side minimum size of 14 in. (6 mm) diameter.
to the Bed post)
? Bolts shall be spaced a
minimum of 1? in. (40 mm) apart
on their
centers for wood beds.
No more than ? in (6
mm) of thread shall be exposed when
the bolts
are fully tightened in the assembled bed.
Hook-on attachments shall require an
additional action other
26 。Hook-On Side
Rails
(Securely attached to the Bed than an
upward force to disengage.
post)
27. Side
Rails Attachments
28. Guardrails
Shall be
no structural failure of bedside rail fastening
systems
when tested in accordance with 5.4.
Two guardrails shall accompany any bed in
which the
underside of foundation is over
30in (762 mm) from the floor.
Guardrails may
be separate from or integral with the ladder.
Shall be attached so that requires the
intentional release of
fastening device or
cannot be removed unless forces are
applied
sequentially in different directions
The upper
edge of guardrails shall be at least 5in. (130 mm)
above the sleeping surface when a mattress of
a thickness that
is the maximum specified by
the manufacturer’s instructions
is used on the
bed.
With no mattress on the bed, there shall
be no openings in the
rigid bed structure
below the lower edge of any opening of
the
guardrail that would permit complete passage of
wedge
block when tested in accordance with
5.5.
A guardrail may terminate before reaching
the bed end structure,
providing there is no
more than 15 in. (380 mm) between either end of
the guardrail and the bed end structures in
the same plane when
measured at a point 5 in.
(127 mm) above the sleeping surface as
established by the maximum mattress thickness
specified by the
manufacturer. The second
guardrail may terminate before reaching the
bed end structure. There shall be no more than
0.22 in. (5.6 mm)
between either end of the
guardrail and the bed end structure when
measured horizontally between the bed end
structure and the nearest
point on the
guardrail if this guardrail terminates before
reaching the
bed end structure.
For bunk
beds designed to have a ladder attached to one
side
of the bed, the continuous guardrail
shall be on the other side
of the bed.
29.I Upper Edge of Upper Bunk End
Structure
(Refer Criteria for Full
Description)
The upper edge of upper
bunk end structures for at least 50%
of
distance between the two posts at the head and
foot of the
upper bunk shall be at least 5 in.
(130 mm) above the sleeping
surface when a
mattress and foundation of the maximum size
and thickness specified by the manufacturer’s
instructional
literature is used on the upper
bunk.
30. Rigid End
Structure of the Upper There shall be no openings
in the rigid end structures of the
Bunk
upper bunk that will permit the free passage of
the wedge
(Refer Criteria for Full
Description) block when tested in accordance with
5.6.1. It shall apply
only to that portion of
the bed end structure that is above the
foundation support system of the upper bunk.
31. End Structure of the Lower Bunk,
Between Lower Bunk Foundation and
the
Lower Level of Upper Foundation
(Refer to
Criteria for Full
Description)
There shall
be no openings in the end structures of the lower
bunk that will permit free passage of the
wedge block when
tested in accordance with
5.6.2, unless they are large enough
to permit
the free passage of a 9 in.(230 mm) diameter rigid
sphere. It does not apply to openings that are
below the level
of the lower bunk foundation
support system. It shall apply to
that portion
of the bed end structure that is between the level
of the lower bunk foundation support system
and the level of
the upper bunk foundation
support system..
32. Lower Bunk End Structure
All portions of the boundary of any opening of the
lower
(Refer to Criteria for Full bunk end
structure that permits free passage of a 9in (230
Description) mm) diameter rigid sphere also
must conform to the neck
entrapment
requirement when tested in accordance with
5.6.2.3 and 5.6.2.4.
33. Ladders Lean-on
or hang-on ladder must be supplied with each bunk
bed set or incorporated as part of the bed
structure. May be
separated from or integral
with the guardrail. Shall be
attached in a
manner that prevents inadvertent
disengagement, repositioning or tilting when
in use.
The width of the ladder shall be no
less than 10 in. (250 mm)
measured from the
inside of the stiles. Vertical spacing of
ladder steps shall be no greater than 12 in
(300 mm) when
measured from the floor to first
step or between steps.
Vertical spacing may be
up to 16in.(400 mm) when bed
structures are
used as ladders.
Shall be no separation of any
of the attachments of the
foundation support
system to the end structures of the bed
when
tested in accordance with 5.7.1.1 and 5.7.2.
Shall be tested to substantiate care label
content. Children’s
furniture which is not
required to contain a care label but has
a
label present shall be laundered according to
label
instructions only. A general appearance
evaluation shall be
conducted.
34.
*Frame and Fastenings
(Racking test - Metal
beds only)
35. Care Label
36.
Lightfastness (Indoor Use –For Class 4.0 @ 20 hrs
- Test up to 5 majormain components
Hard
Materials Only)
MTL SGS TEST LIST (6)
(Tables (Combines Adult and Children’s sizes,
IndoorOutdoor, for the following styles:
Dining, camping, occasional and coffee tables,
desks, nightstands, work bench, potting bench,
storage
bench)
Quality test
standardmethod
ng DesignFeatures(标签
ctions(用发说明书)
Criteria
The
actuality must keep consistency with the
claim.
Results
Shall be included
if necessary. Shall include assembly,
mounting, use, maintenance, cleaning and
safety information
as required in the
language(s) applicable to the destination
country(s) with no errors or spelling
mistakes. Shall be easy
to follow and
accurate.
Report actual. Shall comply with any
claims (-0%, +3%)
3.
product
sizeweight产品尺寸
重量
4. Costco Plastic Bag
Warning
If plastic bags (of any thickness)
with a perimeter of 14 inches or
greater are
used in inner packaging, the following warning
statement
Statement
must be printed on
at least one side of each bag in English, French
and
Spanish:
5. Lead In Surface
Coating
6. Workmanship Level
Shall not
exceed 600 ppm (0.06% by weight) total lead
?
?
?
?
No major defects
No
components missing, malformed or fractured
No
hardware missing
Smoothly ground welds, not
over-ground and free of
pits and splatter
? No burrs
? No loose components and
unsecured fastening where
rigidity is required
? In the case of wood (e.g. laminates) proper
and
uniform adhesion
? No scratches,
dents, cracks, marred or discolored
surface
? In the case of molded plastic, consistent
and concise
form and no defects evidencing of
overuse of mold.
? Finished edges and seams
7. Sharp Points and Edges
8. Cross Cut Adhesion
? Accurate and
consistent painting
? Components even in
color, uniform clarity
Shall have no sharp
edges or sharp points on any component
other
than those required for functional use.
Plating finish must stay affixed – using a
utility knife, cut a
grid of 16 squares. Use
3M masking tape (#202), apply to
the grid.
Remove to see if plating finish remains intact.
9. Glass Top Thickness (Raw Edge If less than
7.6 mm, tempered glass required. If 7.6 mm or
(mm) greater, tempered glass not required.
10. Glass top Thickness (Encased) If less than
4.6 mm, tempered glass required. If 4.6 mm or
(mm) greater, tempered glass not required
11. Stability – Static (If Applicable – Shall
withstand an 8° angle of incline, in the least
stable
Test Filled and Unfilled.) positioning
and configuration, without tip over.
11
Effects Of Extreme Temperature 24 Hours At -32° F
And 140°F - No failure
12. Resistance To
Corrosion (Metal Shall withstand 24 hours in 1%
salt spray (fog) with no
Components)
corrosion or visual change.
13. Effects Of
Humidity No change after 24 hours. @ 95% RH &
100°F
14. Stain Resistance- (Do not test on
Various food materials – should resist permanent
picnic table racks) staining.( After 2 hours,
remove)
1. French’s Mustard t2. Heinz
Ketchup3. Ragu Spaghetti sauce
(original) “
9. Folgers Instant Coffee 5. Welch’s Grape
Juice6. Kraft
BBQ Sauce (original) Red Wine
15 Resistance to Scratching Marring
No
scratching or marring of surface (3 cycles of 6”
back and
Other Surfaces forth.)Conduct
with and without levelers .Note if levelers
become bent or come off. Note any damage
defects
(bentbroken levelers)
16. Caster
Performance (If Supplied)
17. Cycle Test Test
for Moving
Components (Drawers, Doors,
Keyboard Trays, Drop Leaf, Locking
Device,
etc)
18. Folding Mechanisms and Hinges
Max
5 Lbs. pull to move under 200 Lbs. load
100
times cycles use of moving components – no
failure and
all components must have and
maintain a smooth uniform
movement throughout
each cycle. (All functional parts must
be
evenly aligned at the start of the test and remain
evenly
aligned.)
Shall meet the
requirements to eliminate the possible
crushing, laceration or pinching hazards that
might occur in
folding mechanisms and hinges.
19. Moisture Content (%)(Solid 8% - 12% (Do
not test on MDF)
Wood Only)
20. Resistance
To Hot Water Pour 25 ml of boiling water and allow
cooling. Dry surface.
Shall be no graying
or spotting.
21. Cap Removal Strength (On end
of Shall not separate minimum holding force @ 5.0
lbs.
tubes) OR (Cap Covers on Screw
Ends)
22. Caster Performance (If Supplied)
23.
Shelf Loading Capacity
Max 5 lbs pull to move
under 200 lbs load.
Max 14 inch deformation.
Test load dependant on shelf
width and depth:
Report deformation, shelf width and load
applied to shelf
<8
inch depth, (3 lbs x shelf width-inch)
8-16 inch depth, (5 lbs x shelf width-inch)
>16 inch depth (7 lbs x shelf width-inch)
24.
Drawer Loading Capacity
25. Drawer Operability
Max 14 inch deformation @ 10 lbs distribute
loaddrawer
Max 10 lbs pull force with 10 lbs
distributed drawer load
26
Distributed Load Test On Max 14 inch deformation
when 30 lbs distributed test load is
Keyboard
Tray applied on surface for 60 minutes. No
malfunction in
operability shall be noted
after the test.
27. Keyboard Tray Operability
PERFORMANCE – TABLES, DESKS,
BENCHES (TYPE
I)
After distributed load of 10 lbs is applied
to the tray, it should
open with a maximum 5
lbs pull force
Use this section for Dinette,
Casual, Card Tables, Desks,
Work Benches,
with all components such as leaves, levelers.
*If levelers are provided, test with and
without levelers at
additional cost.
*If
leaves are provided, test additionally in largest
configuration at additional cost.
* If
both are provided, test with and without leaf &
levelers
in place
29.Distributed Load
Capacity
Max 14 inch deformation and no
malfunction in any
component when a uniformly
distributed test load is applied
on the
surface for 30 minutes.
Glass top: 100 lbs
Non-glass tops for outdoor use with height 24
inches or less:
400 lbs
The load applied
shall be based on surface area if top is not
glass
Adultchildren
>4 sq ft:
adult- 40 lbssq ft, children’s - 30 lbssq ft
< 4 sq ft: adult - 60 lbssq ft, children’s -
50 lbssq ft
Note: max load: 400 lbs (adult),
200 lbs (children)
No structural failure and
max 12 inch deformation when test
load is
placed on 12 inch diameter disc located such that
the
center of the disc is 6 inch from the edge
of the top surface
for 5 minutes.
Glass
top: 100 lbs
The load applied shall be based
on surface area if top is not
glass
Adultchildren
>4 sq ft: adult - 300
lbs, children’s - 200 lbs
< 4 sq ft: adult
- 275 lbs, children’s - 175 lbs
Must not have
any one leg lift off the floor when test load is
applied to a 12 inch disc located so that the
edge of the disc is
1 inch from the edge of
the top surface
Glass top: 100 lbs
The
load applied shall be based on surface area if top
is not
30. Concentrated Load Test
31. Stability
glass
Adultchildren
>4 sq ft: adult - 100
lbs, children’s - 75 lbs
< 4 sq ft: adult -
90 lbs, children’s - 65 lbs
32. Leg Strength
No structural failure at 75 lbs (40 lbs if folding
legs or if
children’s furniture) applied to
each leg type at 1 inch from
the end of the
leg. Force is applied in four directions
(forward, rearward, side to side)
No
structural damage or deformation when the unit is
raised
45 degrees from the floor
No
structural breakage, 160 lbs test load free falls
from 6 inch
to land in center of table (1
drop.) If chair has levelers,
conduct test
with levelers fully extended then rotated inward
two revolutions.
Must be serviceable
without any damage or malfunction
when one
end of the unit is lifted and then dropped from a
height of 10 inch
Shall remain stable
when tipped 8 degrees.
33.
RockingRacking Test
(Folding Table Only)
34. Impact Durability (Only Perform
On
Non-Glass Outdoor Tables. Not
Intended For
Children’s Tables Which
Have A Height Of 24
Inches or Less)
35. Drop Impact Test
36.
Stability Tip Test
(Bistro Table Only)
PERFORMANCE –COFFEE TABLES
(TYPE II)
Use this section for Coffee tables only
37.Distributed Load Capacity
Max ? inch
deformation and no malfunction in any
component when a uniformly distributed test
load is applied
on the surface for 30
minutes.
Glass top: 50 lbs
Non-glass tops
for outdoor use with height 24 inches or less:
400 lbs
The load applied shall be based on
surface area if top is not
glass
> 4 sq
ft - 30 lbs sq ft
< 4 sq ft - 60 lbs sq ft
note: max load 400 lbs
No structural
failure and max 12 inch deformation when test
load is placed on 12 inch diameter disc
located such that the
center of the disc is 6
inch from the edge of the top surface
for 5
minutes.
Glass top: 50 lbs
The load
applied shall be based on surface area if top is
not
glass
>4 sq ft - 200 lbs
< 4
sq ft - 175 lbs
Must not have any one leg
lift off the floor when test load is
applied
1 inch from the edge on 12 inch disc
Glass
top: 50 lbs
The load applied shall be based
on surface area if top is not
38.Concentrated Load Test
39.Stability
glass
>4 sq ft - 75
lbs
<4 sq ft - 65 lbs
40.Drop Impact
Test
Must be serviceable without any damage or
malfunction
when one end of the unit is
lifted and then dropped from a
height of 10
inch
No structural failure at 75 lbs (40 lbs
if folding legs or if
children’s furniture)
applied vertically to each leg type at 1
inch
from the end of the leg. Force is applied in four
directions (forward rearward, side to side)
41.Leg Strength
PERFORMANCE- END
TABLES
Use this section for End tables, night
stands
OR NIGHTSTANDS (TYPE III)
42.Distributed Load Capacity
Max 14 inch
deformation and no malfunction in any
component when a uniformly distributed test
load is applied
on the surface for 30
minutes.
Glass topnight stand: 50 lbs
Non-glass tops for outdoor use with height 24
inches or less:
400 lbs
The load applied
shall be based on surface area if top is not
glass
> 4 sq ft - 10 lbs sq ft
< 4
sq ft - 20 lbs sq ft
Note: max load 400 lbs
No structural failure and max 12 inch
deformation when test
load is placed on 12
inch diameter disc diameter disc located
such
that the center of the disc is 6 inch from the
edge of the
top surface for 5 minutes.
Glass topnight stand: 50 lbs
The load
applied shall be based on surface area if top is
not
glass
>4 sq ft - 50 lbs
< 4 sq
ft - 25 lbs
Must not have any one leg lift
off the floor when test load is
applied 1
inch. From the edge on 12 inch. Disc
Glass
top: 100 lbs
The load applied shall be based
on surface area if top is not
glass
>4 sq
ft - 50 lbs
< 4 sq ft - 40 lbs
No
structural failure at 75 lbs (40 lbs if folding
legs or if
children’s furniture) applied
vertically to each leg type at 1
inch from the
end of the leg. Force is applied in four
directions (forward rearward, side to side)
Must be serviceable without any damage or
malfunction
when one end of the unit is
lifted and then dropped from a
height of 10
inch
43.Concentrated Load Test
44.Stability
45.Leg Strength (Table)
46.Drop Impact Test
47.
Lightfastness (Indoor Use –For Class 4.0 @ 20 hrs
- Test up to 5 majormain components
Hard
Materials Only)
MTL SGS TEST LIST (7)
(Seating)
(Combines Adult and
Children’s sizes,:Chairs, Barstools, Ottomans,)
Quality test standardmethod
ng
DesignFeatures
ctions
Criteria
The
actuality must keep consistency with the
claim.
Results
Shall be included
if necessary. Shall include assembly,
mounting, use, maintenance, cleaning and
safety information
as required in the
language(s) applicable to the destination
country(s) with no errors or spelling
mistakes. Shall be easy
to follow and
accurate.
Report actual. Shall
comply with any claims (-0%, +3%)
3.
product sizeweight
4. Costco Plastic
Bag Warning
If plastic bags (of any thickness)
with a perimeter of 14 inches or
greater are
used in inner packaging, the following warning
statement
Statement
must be printed on
at least one side of each bag in English, French
and
Spanish:
5. Lead In Surface
Coating
6. Workmanship Level
Shall not
exceed 600 ppm (0.06% by weight) total lead
?
?
?
?
No major defects
No
components missing, malformed or fractured
No
hardware missing
Smoothly ground welds, not
over-ground and free of
pits and splatter
? No burrs
? No loose components and
unsecured fastening where
rigidity is required
? In the case of wood (e.g. laminates) proper
and
uniform adhesion
? No scratches,
dents, cracks, marred or discolored
surface
? In the case of molded plastic, consistent
and concise
form and no defects evidencing of
overuse of mold.
? Finished edges and seams
? Accurate and consistent painting
?
Components even in color, uniform clarity
?
All seams and components in even alignment
?
Accurate and consistent painting
? Components
even in color, uniform clarity
Shall have no
sharp edges or sharp points on any component
other than those required for functional use.
Plating finish must stay affixed – using a
utility knife, cut a
grid of 16 squares. Use
3M masking tape (#202), apply to
the grid.
Remove to see if plating finish remains intact.
7. Sharp Points and Edges
8. Cross
Cut Adhesion
9.
Flammability
Materials
of Upholstery Must
comply with California Bureau of Home Furnishings
Bulletin 116117
Shall meet the
requirements intended to eliminate the possible
hazard that may be caused by changing
clearances or
permanent entrapment and
pinching of fixed openings.(<5mm
or >13mm)
Pour 25 mL. of boiling water and allow
cooling. Dry surface,
Shall be no graying or
spotting
24 Hours At -32° F And 140°F - No
failure
10. Finger Entrapment
11.
Resistance To Hot Water
11 Effects Of Extreme
Temperature
12. Resistance To Corrosion (Metal
Shall withstand 24 hours in 1% salt spray (fog)
with no
Components) corrosion or visual
change.
13. Effects Of Humidity No change
after 24 hours. @ 95% RH & 100°F
14. Stain
Resistance- (Do not test on Various food materials
– should resist permanent
picnic table
racks) staining.( After 2 hours, remove)
1.
French’s Mustard t2. Heinz Ketchup3. Ragu
Spaghetti sauce
(original)
10. Folgers
Instant Coffee 5. Welch’s Grape Juice6. Kraft
BBQ Sauce (original) Red Wine
15
Resistance to Scratching Marring
No
scratching or marring of surface (3 cycles of 6”
back and
Other Surfaces forth.) Conduct
with and without levelers. Note if levelers
become bent or come off. Note any damage
defects
(bentbroken levelers)
16. Caster
Performance (If Supplied)
17. Rear Stability
Max 5 lb pull to move under 200 lb load
Min 35 Lbs. (30 Lbs. children) tipping force
with a 173 Lbs.
(100 Lbs. children) weight
placed on the seat (Strap). Force
is applied
in rearward direction against 1inch obstruction.
Report result when seat is in minimum,
midpoint and
maximum position
The chair is
obstructed by 1 inch bar in the front base,
tipping
force is measured in the 45° to the
test platform. The tipping
force shall not be
less than 40% of the total chair weight.
Min
10 degree with 150 Lbs. (Children 100 Lbs.)
distributed
load, no tip-over
Min 20 Lbs.
pull force after 150 Lbs. (Children 100 Lbs.)
distributed load on the seat, no tip-over
No structural failure or permanent deformation
under 400
Lbs. (225 Lbs. children) static
load for 60 minutes. For
multi seatback
positions, report result when seat back is in
minimum, midpoint, and maximum positions for
20 minutes
each.
No failure under 300 Lbs.
(135 Lbs. children) loading at edge
(6 In.)
18. Front Stability
(Excludes Barstools &
Ottomans)
19. Tip Resistance (Stools Only)
20. Stability (Stools Only)
21. Base
Durability
22. Front Seating Capability
(Excludes Barstools & Ottomans)
23. Impact
Durability No structural breakage, max ? inch
deformation when 225
(*If applicable –
perform with and Lbs. (200 Lbs. folding chairs,
175 Lbs ottomans, 100 Lbs.
without cushion)
children) test load free falls from 6 inch to the
center of the
seat. For multi seatback
positions, report result when seat
back is in minimum, midpoint,
and maximum positions. If
chair has levelers,
conduct test with levelers fully extended
then
rotated inward two revolutions.
24. Back Pull
Durability
25. Arm Strength Test (Vertical)
No failure at 100 Lbs. (60 Lbs. children) for
1 min. applied to
90° from back at 16 inch
above the seat.
No permanent deformation at
300 Lbs. (90 Lbs. children) for
1 min. The
vertical load is uniformly applied through a 5
inch
wide board across both arms – No failure
deformation
No permanent deformation at 75
Lbs. (45 Lbs. children) for 1
min. The load
is applied to the armrest horizontally at the
most forward point of the armrest area.
No
failure or permanent deformation at 75 Lbs. (40
Lbs.
Child folding chairs) applied to each
leg at 1 inch from the
end of the leg. Force
is applied in four directions (Forward,
rearward, side and side) for 1 minute.
26.Arm Strength Test (Horizontal)
27.
Leg Strength
36. Moisture Content (%)
(Solid 8% - 12% (Do not test on MDF)
Wood
Only)
37. Lightfastness
Class 4.0 @ 20 hrs - Test up to 5 majormain
components
MTL SGS TEST LIST (8)
(Seating)
(Combines Adult and
Children’s sizes,:Chairs, Barstools, Ottomans,)
Quality test standardmethod
ng
DesignFeatures
ctions
Criteria
The
actuality must keep consistency with the
claim.
Results
Shall be included
if necessary. Shall include assembly,
mounting, use, maintenance, cleaning and
safety information
as required in the
language(s) applicable to the destination
country(s) with no errors or spelling
mistakes. Shall be easy
to follow and
accurate.
Report actual. Shall
comply with any claims (-0%, +3%)
3.
product sizeweight
4. Costco Plastic
Bag Warning
If plastic bags (of any thickness)
with a perimeter of 14 inches or
greater are
used in inner packaging, the following warning
statement
Statement
must be printed on
at least one side of each bag in English, French
and
Spanish:
5. Lead In Surface
Coating
6. Workmanship Level
Shall not
exceed 600 ppm (0.06% by weight) total lead
?
?
?
?
No major defects
No
components missing, malformed or fractured
No
hardware missing
Smoothly ground welds, not
over-ground and free of
pits and splatter
? No burrs
?
No loose components and unsecured fastening where
rigidity is required
? In the case of wood
(e.g. laminates) proper and
uniform adhesion
? No scratches, dents, cracks, marred or
discolored
surface
? In the case of molded
plastic, consistent and concise
form and no
defects evidencing of overuse of mold.
?
Finished edges and seams
? Accurate and
consistent painting
? Components even in
color, uniform clarity
? All seams and
components in even alignment
? Accurate and
consistent painting
? Components even in
color, uniform clarity
Shall have no sharp
edges or sharp points on any component
other
than those required for functional use.
Plating finish must stay affixed – using a
utility knife, cut a
grid of 16 squares. Use
3M masking tape (#202), apply to
the grid.
Remove to see if plating finish remains intact.
Upholstery Must comply with California Bureau
of Home Furnishings
Bulletin 116117
Shall
meet the requirements intended to eliminate the
possible
hazard that may be caused by
changing clearances or
permanent entrapment
and pinching of fixed openings.(<5mm
or >13mm)
Pour 25 mL. of boiling water and allow
cooling. Dry surface,
Shall be no graying or
spotting
24 Hours At -32° F And 140°F - No
failure
7. Sharp Points and Edges
8.
Cross Cut Adhesion
9. Flammability
Materials
of
10. Finger Entrapment
11. Resistance To Hot Water
11 Effects Of
Extreme Temperature
12. Resistance To
Corrosion (Metal Shall withstand 24 hours in 1%
salt spray (fog) with no
Components)
corrosion or visual change.
13. Effects Of
Humidity No change after 24 hours. @ 95% RH &
100°F
14. Stain Resistance- (Do not test on
Various food materials – should resist permanent
picnic table racks) staining.( After 2 hours,
remove)
1. French’s Mustard t2. Heinz
Ketchup3. Ragu Spaghetti sauce
(original)
11. Folgers Instant Coffee 5. Welch’s Grape
Juice6. Kraft
BBQ Sauce (original) Red Wine
15 Resistance to Scratching Marring
No
scratching or marring of surface (3 cycles of 6”
back and
Other Surfaces forth.) Conduct
with and without levelers. Note if levelers
become bent or come off. Note any damage
defects
(bentbroken levelers)
16. Caster
Performance (If Supplied)
17. Rear Stability
Max 5 lb pull to move under 200 lb load
Min 35 Lbs. (30 Lbs. children) tipping force
with a 173 Lbs.
(100 Lbs. children) weight
placed on the seat (Strap). Force
is applied
in rearward direction against 1inch obstruction.
Report result when seat
is in minimum, midpoint and
maximum position
18. Front Stability
(Excludes Barstools &
Ottomans)
19. Tip Resistance (Stools Only)
20. Stability (Stools Only)
21. Base
Durability
The chair is obstructed by 1 inch
bar in the front base, tipping
force is
measured in the 45° to the test platform. The
tipping
force shall not be less than 40% of
the total chair weight.
Min 10 degree with 150
Lbs. (Children 100 Lbs.) distributed
load, no
tip-over
Min 20 Lbs. pull force after 150 Lbs.
(Children 100 Lbs.)
distributed load on the
seat, no tip-over
No structural failure or
permanent deformation under 400
Lbs. (225
Lbs. children) static load for 60 minutes. For
multi seatback positions, report result when
seat back is in
minimum, midpoint, and maximum
positions for 20 minutes
each.
No failure
under 300 Lbs. (135 Lbs. children) loading at edge
(6 In.)
22. Front Seating Capability
(Excludes Barstools & Ottomans)
23. Impact
Durability No structural breakage, max ? inch
deformation when 225
(*If applicable –
perform with and Lbs. (200 Lbs. folding chairs,
175 Lbs ottomans, 100 Lbs.
without cushion)
children) test load free falls from 6 inch to the
center of the
seat. For multi seatback
positions, report result when seat
back is in
minimum, midpoint, and maximum positions. If
chair has levelers, conduct test with levelers
fully extended
then rotated inward two
revolutions.
24. Back Pull Durability
25.
Arm Strength Test (Vertical)
No failure at 100
Lbs. (60 Lbs. children) for 1 min. applied to
90° from back at 16 inch above the seat.
No permanent deformation at 300 Lbs. (90 Lbs.
children) for
1 min. The vertical load is
uniformly applied through a 5 inch
wide board
across both arms – No failure deformation
No
permanent deformation at 75 Lbs. (45 Lbs.
children) for 1
min. The load is applied to
the armrest horizontally at the
most forward
point of the armrest area.
No failure or
permanent deformation at 75 Lbs. (40 Lbs.
Child folding chairs) applied to each leg at
1 inch from the
end of the leg. Force is
applied in four directions (Forward,
rearward,
side and side) for 1 minute.
26.Arm
Strength Test (Horizontal)
27. Leg Strength
36. Moisture Content (%) (Solid 8% - 12%
(Do not test on MDF)
Wood Only)
37.
Lightfastness Class 4.0 @ 20 hrs - Test up to 5
majormain components
? 包装测试
1. For all
carton dimensions as usual:
Dimensions refer
to the exterior of a carton, measured in inches of
Length x Width x
Height. in inches (mm or m)
1.1 Length (L) is the longer side of the
opening,
1.2 Width (W) is the shorter.
1.3 Height (H) is the length between the
openings on either end.
1.。
一般的纸箱尺寸:
以纸箱外表面为例, 尺寸以英寸为单位: 长 X 寛
X 高, {mm 或 m},
1.1 长是外围的长边
1.2
宽是外围的短边
1.3高是两端外围之间的距离
2。Measure the
weight of carton in pounds (kg)
2.测量纸箱重量,
单位为磅{千克}
3.Vibration Test Period.
3.1
ISTA-1A For Packaged Product 150 lb (68 kg) or
less
Test Duration in Minutes
=
14,200
Vibratory Impacts .
Revolutions Per Minute
(RPM)
3.2 ISTA-1B, 2B For Packaged Product
Over 150 lb (68 kg)
Test Duration in Minutes =
11,800 Vibratory Impacts .
Revolutions Per Minute (RPM)
3.3 (For ISTA)
Procedure
Stop the vibration test half way
Turn the packaging 90? (if possible)
If
the packaging is too large, turn the packaging
180?
Recalculate the cycle time
3。震动测试时间
3.1 ISTA-1A, 150LB或150LB以下, 其震动时间=14,200次频率
3.2 ISTA-1B, 150LB以上, 其震动时间=11,800次频率
3.3
ISTA 测试过程
时间到一半时, 停止震动
如可能,将包装样品转动90度
如包装样品太大, 将包装样品转动180度)
重新计算震动时间
4.Drop
test
4.1 FREE-FALL Drop Sequence
ISTA 1A
(150 lb or less) 1 corner, 3 edges & 6 faces
(Most Fragile bottom corner, if not known,
bottom corner diagonally opposite the
manufacturer’s joint)
ISTA 1B (more than
150 lb) 6 faces
4.2 Drop Height
Drop height
inches
Shipping -1AISTA-1BMod. FedExRule 181
0-21303030
21-25243030
25-40243024
40-41
243018
41-61183018
61-76123018
76-8012241
8
81-100122412
100-15082410
over
1506126
4.
自由落摔测试顺序
4.1 ISTA 1A (150LBS或150LB以下) 1角,
三边, 六面
(底部最脆弱的角, 如无法确定, 就选接缝边的对底角)
ISTA 1B
(超过150LBS) 六面
4.2摔箱高度
Drop
height inches
Shipping -1AISTA-1BMod.
FedExRule 181
0-21303030
21-25243030
25-40243024
40-41243018
41-61183018
61-7
6123018
76-80122418
81-100122412
100-1508
2410
over 1506126