SMART Disk Errors
/var/log/messages
These messages are logged with the service set to smartd. The line
therefore start as follows
Nov 14 16:08:23 lsfnfs02 smartd[17081]:
Many messages then follow with
Device: /dev/twe0 [3ware_disk_01]
Since this text is the same for most messages, it is not shown in the
message contents below.
Message
Action
not
capable
of
SMART
self-check
Replace disk using
DiskWinVendorCall

Error
SMART
Values
Read
failed:
Input/output error
Input/output error
Replace disk mentioned in the next line
using
DiskWinVendorCall

Read SMART Self Test
Log Failed
Replace disk using
DiskWinVendorCall

Device
/dev/sda,
please
try
'-d
An error in the NCM component for Smartd
3ware,N'
has failed to configure the 3Ware
controller entries correctly for smartd.
Contact the disk support for analysis
scsiModePageOffer: raw_curr
Caused
by
entries
for
a
3ware
RAID
unit
in
too small, offset=106
the /etc/. 3ware
Device: /dev/sda, Bad IEC
configurations should not have the
(SMART) mode page, err=5, skip
entries for /dev/sd in , only
device
the ones for the 3ware physical disks.
Check the CDB profile and the response
from smartctl -d /dev/sda
Currently unreadable (pending)
If
the
number
of
sectors
which
are
pending
sectors
is greater than 5, create a vendor call
DiskWinVendorCall
. Otherwise, keep
watching since the number may increase
Offline uncorectable sectors If
the
number
of
sectors
which
are
offline
is greater than 5, create a vendor call
DiskWinVendorCall

not ATA, no IDENTIFY DEVICE
The
disk
is
broken
and
should
be
replaced
Structure
using
DiskWinVendorCall

FAILED SMART self-check. BACK
This
message
can
appear
if
the
self
tests
UP DATA NOW!
are
aborted
manually
in
order
to
clear
out
the error log. If this is true, run a
series
of
short
tests
to
clear
the
20
error
log history. If this is not the case, the
disk
is
failing
and
should
be
immediately
replaced through
DiskWinVendorCall

execute
Short
Self-Test
failed.
Replace disk via
DiskWinVendorCall

starting scheduled Short
This is information only. There is no
Self-Test.
error so the message can be ignored
same
Attribute
has
different
ID
This is information only. There is no
numbers: 196 = 196 = 194
error so the message can be ignored
SMART Usage Attribute: 9
This is information only. There is no
Power_On_Hours changed from 57
error so the message can be ignored
to 56
SMART Usage Attribute: 195
This is reported on Seagate disks. It is
Hardware_ECC_Recovered
changed
the time between ECC hardware failures
from 62 to 61
(which
are
recovered
automatically).
This
variable value will vary and does not
indicate a hardware problem unless the
value is very low (e.g. <5). Typical
values around 60.
is SMART capable. Adding to
This is information only. There is no

error so the message can be ignored
opened
This is information only. There is no
error so the message can be ignored
found in smartd database.
This is information only. There is no
error so the message can be ignored
Failed SMART usage Attribute:
The
disk
has
experienced
a
high
temperate
194 Temperature_Celsius.
alarm. A review of the current
configuration should be made urgently
with TSI section since it indicates a
problem with the cooling around the
machine. If this is only a single disk, a
vendor call can be opened via
DiskWinVendorCall

SMART Prefailure Attribute: 8
This is information only. There is no
Seek_Time_Performance changed
error so the message can be ignored
from 249 to 248
SMART Prefailure Attribute: 1
This is information only. There is no
Raw_Read_Error_Rate changed
error so the message can be ignored
from 277 to 276
Warning! SMART ATA Error Log
This
does
not
seem
to
be
fatal
and
happens
Structure error: invalid SMART
on good disk arrays such as with the
checksum.
8006-2LP.
For
the
moment,
this
message
can
be ignored.
# 9 Short offline Completed:
The smart disk test did not complete ok.
read failure
Identify the failing disk using
TsiTodo

and open a vendor call to replace with
DiskWinVendorCall

ERROR: Verify failed: Port #0.
Some verify operations on 8xxx
controllers seem to be reporting failed
verify status to the log but the verify
actually seems to have succeeded. Check
the
status
with
tw_cli
to
see
that
the
unit
is
OK
and
not
DEGRADED.
If
it
is
ok,
there
is
no
problem.
Otherwise,
follow
the
usual
procedures using lemon-host-check to
identify the error
SMART
Support
is:
Unavailable
-
Raise a vendor call to replace the disk
Packet Interface Devices [this
since it is not responding to SMART
device: Array controller] does
commands
not support SMARRT
To
identify
which
disk
has
generated
a
smartd
error,
the
following
steps
should be taken
Smart Test Errors
The smartctl
command gives
access
to the
logs of previous
runs of smartd
to perform tests. For example,
# /usr/sbin/smartctl -l selftest --device=3ware,0 /dev/twe0
smartctl
version
5.33
[i686-redhat-linux-gnu]
Copyright
(C)
2002-4
Bruce
Allen
Home page is /

Warning! SMART Attribute Thresholds Structure error: invalid SMART
checksum.
=== START OF READ SMART DATA SECTION ===
SMART Self-test log structure revision number 1
NumTest_Description Status Remaining
LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 2945
-
# 2 Short offline Completed without error 00% 2930
-
# 3 Extended offline Completed without error 00% 2907
-
# 4 Short offline Completed without error 00% 2883
-
# 5 Short offline Completed without error 00% 2859
Test #1 is the most recent test. New tests can be run manually using
smartctl -tshort or smartctl -tlong.
The tests are
Test
Details
Description
Short offline
Scan the disk in the background sampling for blocks. This
can be re-executed using -tshort
Extended
Read all the blocks on the disk. This can be re-executed
offline
using -tlong.
Conveyance
These
tests
are
run
sometimes
by
vendors
to
test
disks
after
offline
they
have
been
moved.
They
are
not
normally
run
by
us.
These
lines can be ignored.
The NCM component for smartd configures these tests to run once a week
on Sundays for long tests and every day for short ones.
The status can be one of the following
Status
Meaning
Action
Completed without
All ran ok
None required
error
Aborted by host
The machine aborted the
No action to recommend since
test. The exact cause of
cause is not known
this
is
still
not
known
at
this time
Completed: read
Indicates that selftest
Contact vendor to replace
failure
failed to read a block
disk using
while checking the disk
DiskWinVendorCall
. Some
media
vendors require that we wait
until
the
disk
actually
fails
but the smart test results
are generally accepted as
indication
that
the
disk
will
fail.
Completed:
unknown
The cause and severity
Raise a vendor call using
failure
for this message is not
DiskWinVendorCall

known. It is recommended
to run a long self test
and
check
the
results.
If
no fatal error occurs,
contact TSI for
assistance. For disks in
a 3ware RAID array, this
will generally cause a
SMART-ERROR
in
the
tw_cli
show output.
Fatal or unknown
The cause and severity


error
for this message is not
known. It is recommended
to run a long self test
and
check
the
results.
If
no fatal error occurs,
contact TSI for
assistance
Completed:
The cause and severity


servo/seek
failure
for this message is not
known. It is recommended
to run a long self test
and then contact TSI for
assistance
Completed:
Cause not known but seen


handling_damage??
on
some
old
hardware.
May
indicate too much
vibration of the disk.
Run
an
extended
self
test
and then contact TSI for
assistance
Counter Analysis
Counter
Description
1
Raw Read Error Rate
4
Start Stop Errors
Investigations


This has been seen as a failure on
smartctl just before a disk has failed.

-


-


-


-


-


-


-


-



本文更新与1970-01-01 08:00,由作者提供,不代表本网站立场,转载请注明出处:https://www.bjmy2z.cn/gaokao/553204.html
    上一篇:没有了
    下一篇:没有了

的相关文章