报错信息:
Time
星期四
四月
03 2014 03:07:00 GMT+00:00
from MARGINAL to HEALTHY.
星期四
四月
03 2014 03:06:42 GMT+00:00
from HEALTHY to MARGINAL.
星期四
四月
03 2014 03:06:42 GMT+00:00
Warning
Switch
status
change
Warning
1
Switch
status
changed
swd78_02
Information Switch
status
changed
1
FW-1425
swd78_02
Level
Message
Service
Number
C
ount
Message ID
Switch
Switch
8142
Switch
8140
FW-1424
contributing factor Marginal ports: 1 marginal ports. (Port(s) 15(0xf))
Switch
星期四
四月
03 2014 03:06:07 GMT+00:00
Information The
last
fabric
change
1
SNMP-1007
8141
1
FW-1436
swd78_02
happened at: Thu Apr
3 03:06:03 2014
Switch
8139
swd78_02
Warning
星期四
四月
03 2014 03:06:02 GMT+00:00
disabled
星期四
四月
03 2014 01:17:15 GMT+00:00
Switch
8138
1
Port
(ID:
15)
QOS
is
PORT-1010
swd78_02
Information The
last
fabric
change
1
SNMP-1007
happened at: Thu Apr
3 01:17:09 2014
Switch
8137
swd78_02
----------------------------- ------------------------------------
swd78_02:admin> porterrshow
frames
enc
crc
too
too
bad
enc disc link loss loss frjt fbsy
.
.
tx
rx
in
err shrt long
eof
out
c3 fail sync
sig
=============================== ======================
================
0:
2.3g 1.4g
0
0
0
0
0
19
32
0
3
6
0
0
1:
66
68
0
0
0
0
0
13
0
0
21
24
0
0
2:
49m
66m
0
0
0
0
0
0
4
0
3
6
0
0
3:
1.6m 821k
0
0
0
0
0
25
0
0
10
13
0
0
4:
1.2g 1.8g
0
0
0
0
0
0
27
0
3
6
0
0
5:
49m
15m
0
0
0
0
0
0
0
0
5
8
0
0
6:
277m 2.0g
0
0
0
0
0
0
0
0
3
6
0
0
7:
1.0m 540k
0
0
0
0
0
19
0
0
6
9
0
0
8:
267m 257m
0
0
0
0
0
10
0
0
2
4
0
0
9:
2.0g 2.0g
0
0
0
0
0
0
0
0
6
8
0
0
10:
0
0
0
0
0
0
0
0
0
0
0
2
0
0
11:
3.4g 1.5g
0
0
0
0
0
0
18
0
1
2
0
0
12:
19m 230m
0
0
0
0
0
0
0
0
2
4
0
0
13:
3.5m 1.3m
0
0
0
0
0
0
0
0
3
5
0
0
14:
2.6g 1.3g
0
0
0
0
0
8
11
0
6
8
0
0
15:
3.8g 1.0g
47
7
0
0
0
1.4m
2
8
38
58
0
0
swd78_02:admin> portshow 15
portName:
.
.
portHealth: HEALTHY
Authentication: None
portDisableReason: None
portCFlags: 0x1
portFlags:
0x1000490b
PRESENT
ACTIVE
LOGICAL_ONLINE LOGIN LED
portType:
11.0
POD Port: Port is licensed
portState: 1
Online
portPhys:
6
In_Sync
portScn:
16
E_Port
port generation number:
74
portId:
660f00
portIfId:
4302000f
portWwn:
20:0f:00:05:1e:7b:e7:bf
portWwn of device(s) connected:
Distance:
normal
portSpeed: N1Gbps
LE domain: 0
FC Fastwrite: OFF
Interrupts:
1724
Link_failure: 8
.
Frjt:
G_PORT
0
U_PORT
E_PORT
.
Unknown:
0
Loss_of_sync: 38
Fbsy:
0
Lli:
1682
Loss_of_sig:
58
Proc_rqrd:
3153170
Protocol_err: 0
Timed_out:
0
Invalid_word: 1448546
Rx_flushed:
0
Invalid_crc:
7
Tx_unavail:
0
Delim_err:
0
Free_buffer:
0
Address_err:
0
Overrun:
0
Lr_in:
36
Suspended:
0
Lr_out:
15
Parity_err:
0
Ols_in:
15
2_parity_err:
0
Ols_out:
18
CMI_bus_err:
0
Brocade Switches
–
如何确定是
SFP
或是光纤线导致“
Loss of Link
(丢失链接)
”问题
问题描述
:
一个有问题的
SFP
或光纤线会造成丢失与主机,存储或另一台交换机的连 接问题,在交换
机的
error log
中可能有如下显示
:
2007/12/06-23:50:56, [FW-1424], 7682,, WARNING, SWITCH_1, Switch status chan
ged from HEALTHY to MARGINAL
2007/12/06-23:50:56, [FW-1436], 7683,, WARNING, SWITCH_1, Switch status chan
ge contributing factor Marginal ports: 1 marginal ports. (Port(s) x )
.
.
问题解决方法
:
首先确定是由于
SFP
还是光纤线的问题造成链接丢失,执行下面的命令:
检查
porterrshow
命令的输出:
如果仅是
enc out
单独报错主要是因为光纤线的问题。
如果是
enc out
和
crc err
组合报错主要是
GBIC/SFP
的问题。
要确定是 源端还是目标端
SFP
报错,需要再检查
的输出(
x
代表有 问题端口
号)
如果下面两对参数
Lr_in
和
Ols_out
以及
Lr_out
和
Ols_in
的值相同,则表明
SFP
运
行
正
常
< br>如
果
一
个
数
值
明
显
高
于< br>另
一
个
,
连
接
问
题
可
能
出
现
在
交
换
机
连
接
的
对
端
(
或是交换机本身
(
注意:
如果
”O ls_in”
的值高于“
Lr_out
”的值,
问题的根
源大多数情 况与连接的设备相关,
(sending those offline sequences)
并且交换机通过
对此做出响应。
参数解释:
enc_out -> Encoding error outside of frames
crc err -> Frames with CRC errors
Lr_in -> Link reset In (primitive sequence), does not apply to FL_Port
Lr_out -> Link reset Out (primitive sequence), does not apply to FL_Port
Ols_in -> Offline reset in (primitive sequence), does not apply to FL_Port
Ols_out -> offline reset out (primitive sequence), does not apply to FL_Port
.
-
-
-
-
-
-
-
-
本文更新与1970-01-01 08:00,由作者提供,不代表本网站立场,转载请注明出处:https://www.bjmy2z.cn/gaokao/553252.html
-
上一篇:没有了
下一篇:没有了