运通系列电梯(主板)基本参数
Basic Parameters for LCECPU
参数
出厂值
功能描述
Parameters
Factory setting value
Function description
1
—
1
1
与锁梯层一致
Accord with the
floor with lift lock
1
—
2
6
全集选带运行箭头设
6
1
—
10
5
1
—
12
0
1
—
13
0
1
—
18
1
1
—
23
1
1
—
24
0
1
—
30
1
1
—
32
99
1
—
33
1
1
—
41
1
—
42
1
1
—
43
0
1
—
44
0
巨人通力电梯有限公司
Giant
KONE Elevator Co.,Ltd
Set to 6 of running
direction
开门保持时间(可根据现场情况设定)
Time for door opening (or setting as
job site condition)
带提前开门设
4
Set to 4 if ADO is in use
所有电梯必须设为
0
All
lifts set to 0
单开门设
1
< br>,贯通门设
3
Set to 1 if it is
single entry; set to 3 if it is through
opening car
前门类型
(所有电梯必须设为
1
)
Front door type ( all lift shall set to
1)
后门类型,有后门时设
1
Back door type (set to 1 for back door)
泊梯层,和基站设为一致
Parking floor, set accord with the
ground floor
泊梯时间
The parking time
泊梯模式
The parking
model
用指令登记删除时设
submenu1-0
submenu2-1
Set
submenu1-0
submenu2-1 when
the car call
registered
cancel(CRC) is in use.
用防捣乱功能时设
submenu1-1
submenu2-1
Set
submenu1-1
submenu2-1 when
the anti-nuisance
function is in use
关闭此功能两个都设
0
Set to
0 if the two functions are not in use
内召注册时蜂鸣
Call
registered buzzer ( CRB C)
外召忽略允许(所有电梯必
须设为
0
)
Landing call bypassing allowed (should
set to 0)
有司机功能时设
4
,无司机功能设
0
Set to
4 if attendant service is in use; set to 0 without
attendant service
1
—
50
1
并联时
主梯设
1
副梯设
2
,群控时按接线设置
1
,
2
,
3
………
..
The main lifts
set to 1 and auxiliary lifts set to 2 if the
lifts
are
in
duplex;
set
to
1,
2,
3
according
to
cable
connection for group
control.
1
—
51
33
并联和群控时设置,
1
号梯设
33
,
2
号梯设
34
以此类
p>
推多一台梯向上加
1
In duplex or group control,
set to 33 for the first lift; set
1
—
53
2
1
—
54
1
1
—
56
8
1
—
60
1
1
—
61
11
1
—
62
0
1
—
71
3
1
—
72
1
1
—
79
0
1
—
83
1
1
—
92
1
巨人通力电梯有限公司
Giant
KONE Elevator Co.,Ltd
to 34 for the second lift and
increasing 1 in this way for
each added
lift.
重开门类型,重开门一次设
1
,重开门数次设
2
Re-opening type:
set to 1 if re-opening once; set to 2 if
re-opening several times.
最底
层,修改后必须重新进行井道自学习(并联和群
控的最底楼不一致时设置)
The
lowest
floor.
The
full
speed
commissioning
should
be re-done if this
value is changed. (It will be set when
the lifts under group control have
different lowest floor).
群组
容量,两台并联设
2
,群控时根据实际群控台数
设置,
The
group
quantity:
set
to
2
in
duplex
control;
setting
according to the real quantity of lifts
in group control.
消防返回层,和消防层设为一致
Set accord with the fire return floor <
/p>
有消防设
11
,无消防设
0
(消防动作到达消防层后,
若需要轿内消防开关打开
后才可以开电梯的设为
25
)
Set
to
11
if
with
fireman
function;
set
to
0
if
without
fireman function
(the fire
function acted
and lift comes
to
the
fire
return
floor,
if
requiring
the
lift
only
can
be
used after the car fire
switch is opened, then set it to be
25)
消防功能,有消防设
1
,无消防设
p>
0
Set to 1 if with fireman
function; set to 0 if without.
轿顶检修驱动极限
,
(须设为
3
)
Car top inspection running limitation
(should be set to 3)
锁梯返回层,和基站设为一致
The
returning
floor
for
locking
lift:
set
it
same
as
to
ground
floor.
锁梯时轿厢照明状态,关闭设
0
,不关闭设
1
The
condition of illumination during lift locked: set
to 0
if it is closed; set to 1 if it is
open
超载闪烁信号,不闪烁设
0
,闪烁设
1
Flicker
signal
for
overload:
it
is
closed
if
set
to
0;
it
is
open if set to 1.
风扇类型(
1
为自动且带开关,
0
为自动)